Inhaler carton, crash-lock bottom
Crash-lock bottom with tamper-evident tuck top for a metered-dose inhaler.
- Cut
- Crease / fold
- Perforation
Technical profile · sample · view only
EU FMD · inkjet coding
EU FMD (Reg. 2016/161): UI + ATD, online TIJ
Serialised EU pack with 2D code and human-readable data printed online by thermal inkjet into an unvarnished window.
| # | Zone | Label | Position · size (mm) | Details |
|---|---|---|---|---|
| 1 | Serialisation (2D + HRI) | UI: GS1 DataMatrix + HRI | x 69 · y 107.6 26 × 40 |
|
| 2 | Varnish-free area | Unvarnished coding window | x 67 · y 105.6 30 × 44 |
|
| 3 | Braille | Braille: name + strength | x 103 · y 56.6 40 × 12 |
|
| 4 | Reading direction | Reading direction: top closure up | x 118 · y 92.1 10 × 24 |
|
| 5 | Glue area | Side seam glue | x 1.5 · y 53.1 13 × 102 |
|
| 6 | Glue area | Glue contact (inside of Side B) | x 169.5 · y 53.6 10 × 101 |
Matching unvarnished strip on the inside of the joint (reverse side). |
| 7 | Barcode / Pharmacode | Pharmacode (Laetus) | x 22 · y 57.6 6 × 30 |
|
| 8 | Visual edge mark / colour code | Strength colour band | x 148 · y 51.6 32 × 4 |
|
| 9 | Tamper evidence (ATD) | ATD: seal label position | x 113 · y 29.4 20 × 12 |
|
Coordinates in mm from the top-left corner of the die extent (y downwards), as in the PDF's TrimBox.